Discover
HVAC School - For Techs, By Techs
HVAC School - For Techs, By Techs
Author: Bryan Orr
Subscribed: 4,118Played: 276,119Subscribe
Share
Description
Real training for HVAC ( Heating, Ventilation, Air Conditioning and Refrigeration) Technicians. Including recorded tech training, interviews, diagnostics and general conversations about the trade.
945 Episodes
Reverse
In this short podcast episode, Bryan talks about compression ratio and compressors, particularly why you see more suction pressure when the compressor unloads and what that means for the HVAC system's operation. When the compressor drops into low-stage or unloads, the suction pressure goes up. Regardless of the cause of reduced pumping, the head pressure will also drop as the suction pressure rises. If the conditions stay the same and the compressor stages down, the pumping capacity drops; the compressor moves less vapor while the evaporator still needs to absorb the same amount of heat. However, if the indoor airflow also drops along with the compressor stage, the load on the evaporator also changes and drops the suction pressure. Dynamic metering devices (such as TXVs and EEVs) also need to equalize and factor into the compression ratio. We should understand the sequence before condemning a compressor and then use that sequence in diagnosis. To troubleshoot and test staging, we want to identify the equipment and sequence (including how the manufacturer wants us to test staging) and then record everything at each stage or at least a few different points. We want to see how the equipment responds, such as if one part does not respond when the compressor drops to a lower stage. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, TruTech Tools, and the 2027 AHR Expo. Resources Compression Ratio (video) Why Compression Ratio Matters (tech tip) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
In this episode, Bryan welcomes back Louise Kellar of UEi Test Instruments for a deep dive into getting more out of a digital clamp meter than the basic volts, amps, and ohms most techs rely on every day. The tool in the spotlight is UEi's High Accuracy Clamp Meter (HAC), which is accurate when dealing with the low current draws common on modern condenser fan and blower motors and is critical for reliable wattage and capacitor-under-load testing. The podcast also walks through a series of lesser-used but valuable meter functions, including microamp measurement for flame rectification testing, diode testing for diagnosing boards on mini-splits, the Low Z setting for eliminating ghost voltage readings and safely bleeding capacitors, and the safety-locking temperature toggle that prevents technicians from accidentally crossing voltage and thermocouple leads. Bryan and Louise also cover common mistakes, such as not knowing when to use continuity or resistance and auto-ranging mistakes, as well as some crucial takeaways about true RMS measurements, temperature settings, and CAT safety ratings. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, and Filtrete. Resources UEi products, manuals, and resources HVAC Multimeter Skills: Continuity vs. Resistance & Diode Testing (video) CAT Ratings on Electrical Multimeters (tech tip) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
In this short podcast, Bryan and Roman discuss premature coil failure in ductless mini-splits and VRF equipment. These coils are susceptible to a few different types of corrosion. Warmer coil saturation temperatures and shorter runtimes result in lower latent capacity; whatever moisture is on the coil dries on the coil instead of draining out. Minerals and chemicals (including chlorides from bleach or cleaners) interact with the coil and may cause corrosion, including formicary ("ant's nest") corrosion. Leaks and corrosion may be environmental rather than entirely attributable to manufacturer defects. Technicians can use proper cleaners with correct dilution ratios and rinse the coils. In situations where the environment contributes to coil corrosion, such as with substances off-gassing or dealing with coastal air, we will need to dilute the pollutants by ensuring proper ventilation. Dilution needs to be intentional, especially in hot-humid climates, and ventilating dehumidifiers with good filtration may be a good move. Source control and filtration are also good mitigation strategies, and clear, open client communication can help clients understand the problem and make informed decisions about their HVAC system. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, and Fieldpiece. Resources Coil Corrosion w/ Kevin Hart and Bryan Orr Living in a World of Acids (and why HVAC coils are secretly crying for help) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
In this live episode, Bryan sits down with Jim Bergmann of measureQuick and NAVAC trainers Zane and Jesse Stewart for a deep, technician-focused conversation about advanced refrigerant recovery. The group covers diverse system types and environments, including low-ambient recovery. Recovery machines cannot pump straight liquid, which we need to be mindful of during service. That said, vapor-only recovery works fine for small charges, but push-pull recovery becomes worthwhile once a system holds more than roughly ten pounds of refrigerant. Refrigerant and tank contamination, as well as general safety (including tank fill limitations), are a couple of other field challenges worth considering in our recovery best practices. Some best practices to take away from this episode include attaching to the vapor side of the tank (and inverting it), pulling Schrader cores, using large hoses instead of manifold gauges, and keeping the recovery tank cool to eliminate restrictions. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Copeland, Santa Fe Dehumidifiers, and TruTech Tools. Resources: Don't Overfill Recovery Tank Cylinders the Easy Way Recovery Tank Safety Recovery Tank Capacity Push-Pull Recovery Recovery Best Practices w/ NAVAC HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
In this short podcast episode, Bryan and Roman talk about the A2L & refrigerant transition again, particularly sensors on R-454B and R-32 equipment. Since the beginning of the A2L transition, we have seen the equipment evolve and begin requiring accessories, including refrigerant sensors and blower recirculation systems (BRS) or dissipation boards. In a BRS, the blower turns on and dilutes the refrigerant in the space to keep the refrigerant concentration below the lower flammability limit (LFL) and prevent ignition. Some systems may also have isolation valves and pump themselves down whenever the A2L sensor trips. These sensors use MOS technology, which measures gas changes by tracking electrical connectivity shifts; they have limited lifespans and can become corrupted over time. In the field, you may notice a running fan without the outdoor unit running. Some diagnostic boards might give you error codes, but if you don't and don't have 24V when you troubleshoot the issue, you may want to check the sensor. The sensors could be wet, tripped by VOCs, or even have been cut out. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, TruTech Tools, Fieldpiece, and Filtrete. Resources A2L Dissipation Boards and Leak Sensors HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.





