Two Minnesota sprinkler fitters: FIELD, a beat-up old journeyman who's hung more pipe than you've walked past, and CODE, a cocky apprentice who's read the book twice and thinks that makes him dangerous. Raw, 18+ late-night talk on the MN Journeyman Sprinkler Fitter exam, built on the MSFC, NFPA 13, 14 and 25 and Minnesota rules, checked against the text, not barstool lore.
Made by fitters who still work the job, for the brothers and sisters trying to get that card. Pair it with the MN Journeyman Exam Prep app. New episodes every day.
Made by fitters who still work the job, for the brothers and sisters trying to get that card. Pair it with the MN Journeyman Exam Prep app. New episodes every day.
207 Episodes
Reverse
NFPA 25 Standpipe & Hose ITM: Annual Inspections, 5-Year Flow & Hydro Tests, Hose Valves & Pressure-Regulating Devices | MN Journeyman Exam PrepNFPA 25 Chapter 6 for standpipe and hose systems: what gets inspected and when, the 5-year flow test at the hydraulically most remote hose connections, the 5-year hydrostatic test on manual and dry standpipes, hose valve and pressure-regulating device testing, and where Chapter 6 hands you off to Chapter 13. Minnesota tie-in: the Minnesota State Fire Code points water-based systems to NFPA 25, and the Minnesota annual roll-up exception covers weekly through annual items only, not the 5-year tests.Two fitters, a lot of swearing (18+), a lightning round, and a war story. Numbers are from NFPA 25-2020 (core numbers checked against 2017 and unchanged); the Minnesota State Fire Code (2020) with Minn. R. 7511 amendments. NFPA 25-2023/2026 text and NFPA 1962 were not available for this recording, so check the edition your exam uses.App news: Minnesota Journeyman Exam Prep is still in testing with Google and coming soon to Google Play (Android only). Sorry, Google's still testing it. Thank you to our closed testers.Want to help test? Join the tester group first, then opt in (Android only):Tester group: https://groups.google.com/g/mn-journeyman-exam-testersTester link: https://play.google.com/apps/testing/com.mnfireexamprep.app
NFPA 13 Design Approaches: Pipe Schedule, Density/Area, Remote Areas & Room Design | MN Journeyman Exam PrepNFPA 13 design approaches: pipe schedule versus hydraulic calculation, the four pipe-schedule doors, density/area curves, remote-area increases and floors, the room design method, and how adjustments compound. Minnesota overrides are the main event: undetermined use is Ordinary Hazard Group 2 with a 3,000-square-foot minimum, chemistry labs and wrestling or gymnastic rooms are at least OH2, new systems and additions need a 5 psi margin including hose (13D excepted), and a waterflow test used for design can be no older than 36 months before the working plan submittal. This is not a rerun of Hazen-Williams math or occupancy definitions.Two fitters, a lot of swearing (18+), a lightning round, and a war story. Numbers are from NFPA 13-2019 with 2016 section numbers where Minnesota still points (Minn. R. 7511.8000), plus Minnesota amendments in Minn. R. 7511.0903 where they apply. Check the edition your exam uses. NFPA 13-2022/2025 text was not available for this recording.App news: Minnesota Journeyman Exam Prep is still in testing and coming soon to Google Play (Android only). Thanks to our testers.Want in early? Join the tester group first, then opt in (Android only):Tester group: https://groups.google.com/g/mn-journeyman-exam-testersTester link: https://play.google.com/apps/testing/com.mnfireexamprep.app
NFPA 13 In-Rack Sprinklers: Location, Spacing, Barriers & Design Criteria | MN Journeyman Exam PrepIn-rack sprinklers in NFPA 13 Chapter 25: 40,000-square-foot system size, separate control valves, K-factors, water shields, 6-inch clearance, vertical and horizontal location, face sprinklers, solid shelves, barriers, the 25.8 independent option, and the 25.12 design rules that were actually readable. Ceiling type changes the in-rack spacing. Tables 25.12.2.1 and 25.12.3.1 are pointed to, not invented. Minnesota still pins 13-2016, so the short installation chapter is 8.13 on that desk.Two fitters, a lot of swearing (18+), a lightning round, and a war story. Numbers are from NFPA 13-2019 with 2016 section numbers where Minnesota still points (Minn. R. 7511.8000), plus Minnesota amendments in Minn. R. 7511.0903 where they apply. Check the edition your exam uses. NFPA 13-2022/2025 text was not available for this recording.App news: Minnesota Journeyman Exam Prep is still in testing and coming soon to Google Play (Android only). Thanks to our testers.Want in early? Join the tester group first, then opt in (Android only):Tester group: https://groups.google.com/g/mn-journeyman-exam-testersTester link: https://play.google.com/apps/testing/com.mnfireexamprep.app
NFPA 13 CMSA Sprinklers: Installation, Spacing & Storage Applications | MN Journeyman Exam PrepControl mode specific application sprinklers: Chapter 13 installation and Chapter 22 storage applications. Not ESFR and not extended coverage. Pendent exception (9.5 and the listing, in lieu of 13.2), 80-to-130 square feet, 12- or 10-foot spacing, 8-foot minimum, 6-to-8-inch deflectors, 36-inch clearance to storage, dry-system high-temp in storage, and how the Chapter 22 tables are built (pressure and a number of heads). Solid shelves need in-rack. Minnesota still pins 13-2016 (8.11 and 8.4.7 on that desk). Unread table rows were not invented.Two fitters, a lot of swearing (18+), a lightning round, and a war story. Numbers are from NFPA 13-2019 with 2016 section numbers where Minnesota still points (Minn. R. 7511.8000), plus Minnesota amendments in Minn. R. 7511.0903 where they apply. Check the edition your exam uses. NFPA 13-2022/2025 text was not available for this recording.App news: Minnesota Journeyman Exam Prep is still in testing and coming soon to Google Play (Android only). Thanks to our testers.Want in early? Join the tester group first, then opt in (Android only):Tester group: https://groups.google.com/g/mn-journeyman-exam-testersTester link: https://play.google.com/apps/testing/com.mnfireexamprep.app
NFPA 13 Extended Coverage Sprinklers: Upright, Pendent & Sidewall Installation | MN Journeyman Exam PrepExtended coverage sprinklers in NFPA 13 Chapter 11: listing, protection area, spacing for upright, pendent, and sidewall heads, deflectors, obstructions, slope, and pockets. This is not CMSA and not ESFR, and yesterday's residential 1-to-4 is not today's 20-foot tape. Minnesota still pins NFPA 13-2016, so the hang lives in 8.8 and 8.9 on that desk.Two fitters, a lot of swearing (18+), a lightning round, and a war story. Numbers are from NFPA 13-2019 with 2016 section numbers where Minnesota still points (Minn. R. 7511.8000), plus Minnesota amendments in Minn. R. 7511.0903 where they apply. Check the edition your exam uses. NFPA 13-2022/2025 text was not available for this recording.App news: Minnesota Journeyman Exam Prep is still in testing and coming soon to Google Play (Android only). Thanks to our testers.Want in early? Join the tester group first, then opt in (Android only):Tester group: https://groups.google.com/g/mn-journeyman-exam-testersTester link: https://play.google.com/apps/testing/com.mnfireexamprep.app