The Poly Processing Podcast, "News You Can Use," offers a concise 10-15 minute audio recap of the latest updates, resources, and factory news tailored specifically for our distributor partners. Tune in while you're driving, working out, or waiting in line - it's designed to keep you informed and save you time.


🔧 PRODUCT SPOTLIGHT: EPDM Expansion Joints – A Cost-Saving Alternative


Many customers continue specifying the standard Teflon® flex joints — and while those are dependable — they might be overlooking a major cost-saving opportunity.


The EPDM Expansion Joint is compatible in many applications and is a less expensive alternative.



  • Use Case: Best when paired with a transition fitting.

  • Savings: Up to $500–$700 per installation compared to Teflon joints.

  • Availability: Listed in PolyQuote under “Bellows EPDM.”


đźź© Pro Tip: For non-chemical applications where EPDM compatibility is suitable, suggest this upgrade to maximize value.


🛢️ KNOW YOUR TANKS: Molded-in Pocket Fittings on SAFE-Tank® Systems


A frequent question from the field: Which SAFE-Tanks come with molded-in pocket fittings? Good news — we’ve added a dedicated column with a PF in the header on the SAFE-Tank product page on PolyProcessing.com.


Here's what you’ll find:



  • A downloadable PDF showing each tank’s pocket fitting availability.

  • Pocket fitting counts and locations (some tanks offer up to 4).

  • Only one pocket fitting per tank allowed due to stress control.


🟩 Reseller Tip: For SAFE-Tanks under 2,500 gallons, recommend molded-in pockets as a smart installation option — but caution customers against using fittings on opposing sides.


📡 NEW FEATURE: Swiveling Radar Fitting


Radar sensors are gaining popularity. To meet this demand, we now offer a swiveling radar fitting that allows users to adjust the sensor’s aim.


What this means for your customers:



  • Improved installation flexibility on tank domes.

  • Enhanced accuracy in level monitoring.

  • Seamless integration into quotes (ask for “swivel radar fitting”).


đźź© Why it Matters: This small accessory can prevent costly installation errors and improve radar sensor performance.


🚨 COMING SOON: 10,500-Gallon SAFE-Tank®


We’re excited to announce a new addition to the SAFE-Tank lineup: the 10,500-gallon SAFE-Tank, shipping starting September 2025 from our Monroe, LA plant.


Details:



  • Drawings and specs now available online at www.polyprocessingpartner.com.

  • Early demand is high — encourage your clients to place orders ASAP.

  • Pricing is available in PolyQuote.


đźź© Sales Strategy: Offer this double wall tank as a solution for bulk users looking to reduce frequent chemical refills and site delivery costs.


🔥 HEAT MAINTENANCE SYSTEMS: What Sets Ours Apart


We spoke with Scott Brenneman of HTD — our long-time heat panel supplier — for insights on how our heat maintenance systems stand out from the competition.


Key Differentiators for Resellers:



  • Parallel Circuit Design

    Unlike series-based systems, ours use multi-path parallel heating elements. If one path fails, heat continues uninterrupted — a major reliability advantage.

  • Digital Controls

    The standard 2XTC controller offers:

    • Process temp. display (default: 60°F).

    • High/low alarms (default: 100°F / 40°F).

    • LED indicators for alarms and heater status.

    • Alarm relays connectable to SCADA or DCS systems.

    • 4–20 mA output for remote monitoring.



  • Adjustable Parameters

    Alarms and deadband (default 2°F) are user-adjustable — great for field tuning.

  • QR Code Access

    Every controller includes a QR code to the full operating manual and recommended settings.

  • Current Monitoring Alarm

    Disabled by default but can detect heater failure or connection loss when configured correctly.


Power Requirements:



  • Default: 120V

  • Optional: 240V configurations

  • Amp draw depends on heater quantity (1–6 pads typically)

  • NEC-compliant: Requires equipment-level ground fault protection (30 mA) — not personnel protection (5 mA)


Heat Maintenance System Video – Click here to watch the short heat maintenance system video.


🟩 Talking Point: Highlight that our heat panel systems are not just effective — they’re engineered for resilience, control, and smart integration.


👥 SUPPORTING YOU, OUR PARTNERS


We hope this newsletter helps you better support your customers and strengthen your expertise on Poly Processing solutions. Whether you're quoting a new tank system or assisting with troubleshooting, the right knowledge can help close the sale.


For product data sheets, drawings, and blog articles:

➡️ Visit polyprocessing.com

➡️ Use PolyQuote to spec and price systems instantly.

➡️ Reach out to your Regional Sales Manager for sales. enablement support


Next Issue: July 2025

Stay tuned for more technical tips, product launches, and strategies to help you succeed!

Comments 
00:00
00:00
1.0x

0.5x

0.8x

1.0x

1.25x

1.5x

2.0x

3.0x

Sleep Timer

Off

End of Episode

5 Minutes

10 Minutes

15 Minutes

30 Minutes

45 Minutes

60 Minutes

120 Minutes

Poly Processing News You Can Use, June 2025

Poly Processing News You Can Use, June 2025

polyprocessing